This tool runs the ground-supported slab checks of Concrete Society Technical Report 34, 4th edition, Section 7: Meyerhof yield-line capacity for point loads at internal, edge and corner positions, punching shear, and Hetényi's elastic analysis for line and uniformly distributed loads. Enter one load arrangement to see every check, the one that governs, and the thickness that would satisfy them all.
"Realistic assessment of the combined effects of load-induced stresses and shrinkage is problematical... The approach taken in this report for ground-supported floors is therefore to not take into account the effect of shrinkage-induced stresses..."
This is why we built SLABS™.
Read more about our why, learn about slabs-on-ground, or see our workshops and demos.
Limitations of the TR34 method
TR34 is the guide most used outside the United States for industrial floors, and its point load method is easy to run. This tool reproduces it as published. Its limits are worth knowing before a result is used to set a slab thickness.
Not a first-crack check, and by its own account not a collapse check either. The Meyerhof equations assume the bottom of the slab has already cracked and yielded under the load, and stop when the top is about to crack. TR34 notes that "this is not a true ULS as the floor will not have collapsed" and that "there are no separate design checks for serviceability" (Section 7.1). A pass means no cracks are expected on the top surface under that one load. It says nothing about the cracks underneath.
No shrinkage, curling or warping. TR34 says so directly: its approach is "to not take into account the effect of shrinkage-induced stresses" and to manage them through the mix, the sub-base and the joint layout instead (Section 7.1). The slab is assumed flat and "fully supported by the ground." Stress from temperature and moisture gradients, and the loss of support at lifted edges and corners, have no input.
Joints are a percentage and a dowel strength. Load transfer is 15% for aggregate interlock at a 1.5 mm opening plus the strength of the dowels, capped at 50%. Joint opening is not calculated, and dowel stiffness and how both change with panel size and shrinkage are not modeled.
Panel size is not an input. The equations assume a slab large enough for the mechanism to form. Short panels and long jointless panels get the same answer.
One load group at a time. A lift truck passing a loaded rack leg, or adjacent rack rows interacting beyond the dual and quadruple cases, cannot be combined.
The strength comes from a beam. Flexural strength is derived from cylinder strength and slab depth, and fibre capacity from 150 mm notched beams tested to EN 14651. The residual strengths are converted to a slab moment through assumed stress blocks, and TR34 forbids extrapolating to a dosage or fibre that was not tested. Neither test is of the slab on its support.
Distributed loads switch theory, and joints are ignored. Line and distributed loads are checked elastically with a global factor of 1.5, while point loads are checked plastically with partial factors of 1.2 to 1.6 on load and 1.5 on material. TR34 states that "joints have been ignored for UDL calculations" (Section 7.12), and that this "has not been known to result in failures." Equation 36 compares an elastic sagging moment with Mp, a cracked, reinforced capacity, as printed. Juhász and Schaul (2019) point out that because these formulas are linear elastic, reinforcement has no real effect on the result, that lowering the safety factor to compensate departs from the partial factor method of the Eurocodes, and that the formulas for a defined load position "are inaccurate" and need revising or restricting. The tool offers Mn in place of Mp for Equation 36 for that reason.
Fatigue is a road method. Appendix E is "an empirical approach derived from TRRL Research Report 87," a thickness design method for concrete roads, and the basis of TR66 for external paving. It counts standard 8160 kg axles, applies to axles up to 25,000 kg on a foundation of at least 100 MPa, assumes effective load transfer at every joint, and has no data for fibre-reinforced slabs. It returns a thickness, not a stress, so it cannot be combined with the point load checks.
The ground is one number. A single modulus of subgrade reaction stands in for the whole support system.
For how these gaps compare with the ACI 360R-10 methods, and what a mechanistic-empirical design adds, see If You Can't Model It, You Can't Prevent It and its companion paper, From Westergaard and Meyerhof to Mechanistic-Empirical Design.
Limitations of this tool
Beyond the limits of TR34 itself, this tool does not cover everything in the report. Check these items by other means where they apply.
- Dowel and plate dowel capacity (Section 6.5 and Appendix D) is not calculated. Enter it as a capacity at the edge if you have it.
- Pile-supported slabs (Section 8) are not covered, including their fatigue reduction of moment capacity (Equations 38 and 39).
- One load arrangement at a time. Point loads, a line load and a distributed load can be entered together, but each is checked on its own, as TR34 does.
- Joints in distributed loads. Distributed loads near joints are not checked, following TR34.
- Tyre contact area is the wheel load divided by the tyre pressure, as a square. Solid and polyurethane tyres need the manufacturer's contact area.
- Fatigue traffic is entered as up to three loaded trucks with two axles each. Unloaded return trips, more axles, and wander across the floor are for the user to judge in the number of passes.
- Mezzanine loads. TR34 gives factors of 1.35 on mezzanine dead load and 1.5 on imposed load. The tool's three load inputs use 1.2, 1.5 and 1.6, so enter a mezzanine dead load in the "other static" input as 1.35/1.5 of its value.
- No serviceability or deflection check, because TR34 has none for ground-supported slabs.
- Under development and testing. Results may change as the tool is checked. Verify every value independently before use on a project.
Checked against printed values
Each row is recalculated by the same engine every time this page loads. Load a case to see it in the tool. Printed values are as published; small differences are rounding in the printed figure.
| Printed case | Quantity | Printed | This tool | Note |
|---|
How the calculation works
Materials. fcm = fck + 8. fctm = 0.3fck2/3. Design flexural tensile strength fctd,fl = fctm(1.6 − h/1000)/γm with γm = 1.5. Ecm = 22(fcm/10)0.3 GPa. Poisson's ratio 0.2.
Stiffness. Radius of relative stiffness l = [Ecmh³/(12(1 − ν²)k)]0.25. For line and distributed loads, λ = (3k/Ecmh³)0.25.
Moment capacities. Negative (hogging) capacity Mn = fctd,flh²/6. Positive (sagging) capacity Mp: for fabric, 0.95Asfykd/γs with γs = 1.15; for fibre, (h²/γm)(0.29σr4 + 0.16σr1) with σr1 = 0.45fR1 and σr4 = 0.37fR4.
Fibre plus fabric or bars (Section 6.3). Below 0.15% of the section, Mp = (h²/γm)(0.29σr4 + 0.16σr1) + Asfyk(d − 0.048h)/γs (Equation 8). At 0.15% or more, the neutral axis depth hux comes from equilibrium, 0.64huxfck = (h − hux)[σr4 + 0.5(σr1 − σr4)] + Asfyk (Equation 9), and Mp follows from Equation 10, valid while hux < 0.3d.
Rigorous moment capacity (Appendix C). As an option for fibre and fibre-plus-bar sections, the tool solves the stress blocks of Figures C2.1 and C2.2: tensile strain at the face 3.5/hc up to 0.025, compressive strain up to 0.0035 with a bilinear block above 0.00175, fibre stress varying from σr1 toward σr4 (softening or hardening), and the bar force limited to yield. hux is found by equilibrium (Equation C14) and Mp by moments about the neutral axis (Equation C15). Not valid for h above 600 mm or hux above 0.3d.
Tyre contact area (Section 7.8.1). Where the tyre pressure is known, the contact area is the wheel load divided by the pressure, and the equivalent radius a = √(area/π).
Point loads. Equivalent contact radius a = √(contact area/π). Each position has an equation for a/l = 0 and one for a/l ≥ 0.2, with straight-line interpolation between. The a/l ≥ 0.2 equation is evaluated at the actual a before interpolating, as Structville does; evaluating it at a = 0.2l instead, as one worked example does, gives up to about 2% more. Internal: 2π(Mp + Mn) and 4π(Mp + Mn)/(1 − a/3l). Edge: π(Mp + Mn)/2 + 2Mn and [π(Mp + Mn) + 4Mn]/(1 − 2a/3l). Corner: 2Mn and 4Mn/(1 − a/l). Dual and quadruple internal loads add 1.8x/l or 1.8(x + y)/l to the 2π term, and 1.8x/(l − a/2) or 1.8(x + y)/(l − a/2) to the a/l ≥ 0.2 term. A group is checked as single loads, as pairs, and as a whole. Where a is large enough to make a denominator zero or negative (a ≥ l at a corner, 1.5l at an edge, 3l internally), the equation has left its range: edge and corner capacities are then capped at the internal capacity, and an internal load that large fails with a note to check it as a distributed load.
Load factors (Section 7.2). 1.2 on defined racking, 1.5 on other loads, 1.6 on dynamic loads from materials handling equipment. Material factors are 1.5 on concrete, with or without fibre, and 1.15 on bar and fabric.
Joints (Section 7.9). Effective edge capacity is the free-edge capacity divided by (1 − load transfer), plus the dowel capacity, not more than twice the unaided edge capacity (no more than 50% of the load can cross a joint), and not more than the internal capacity.
Punching. At the face of the contact area, vmax = 0.5k2fcd with k2 = 0.6(1 − fck/250). At 2d, vRd,c = 0.035ks1.5fck0.5, or the Eurocode 2 expression with the fabric ratio if greater, plus 0.015(fR1 + fR2 + fR3 + fR4) for steel fibre and nothing for macro-synthetic fibre. The ground reaction inside the perimeter is deducted from the load. d = 0.75h for fibre and plain slabs.
Line and distributed loads. Line load capacity 4λMun, dropping to 3λMun at a free edge. For an unknown layout, distributed load capacity is 5.95λ²Mn (Equation 35), the worst case of strips π/λ wide with a π/2λ aisle. The sagging case TR34 names in Figure 7.10(a), one strip π/2λ wide, is also checked against Mp at 6.20λ²Mp; the 3rd edition printed it as λ²Mp/0.161 and the 4th gives no equation for it. It governs only where Mp is below about 0.96Mn. Where strip widths and the aisle are known, the tool sums Hetényi's beam-on-elastic-foundation moments from each strip across the whole width, M = q/(4λ²)Σ(±Bλa ∓ Bλb) with Bλx = e−λxsin λx, and checks the peak sagging moment against Mp (Equation 36) and the peak hogging moment against Mn (Equation 37), each for the worst of either strip loaded alone and both loaded. All are compared with the characteristic load, because TR34 treats the 1.5 material factor as the global factor for these cases.
Fatigue (Appendix E). Each axle is converted to standard 8160 kg axles by the fourth power, (axle/8160)4, after multiplying by 1.3 for solid or high-pressure tyres, 1.4 where all traffic brakes or turns at one point, and the Figure E1 factor 2 − s/l where wheels on the axle are closer than l. Multiplying by passes and summing gives the traffic L in million standard axles. With fcm = fck + 7, the required thickness is h = 1935L0.196/fcm0.68 for less than 300 mm²/m of reinforcement (Equation E2) and h = 9141L0.209/(fcm0.663As0.296) for 300 mm²/m or more placed in the top third of the slab (Equation E3, Note 4). Bottom fabric alone uses Equation E2 whatever its area. Axle loads are not factored.
Assumptions and open items
Basis
- Every equation was checked against TR34 4th edition, March 2016 reprint with amendments: Sections 6.3, 6.4, 7.2, 7.4, 7.5 and 7.7 to 7.12, Equations 2, 3, 6 to 15 and 20 to 37, and Appendices C and E.
- The tool reproduces the printed values in the table under "Checked against printed values": TR34 Table 6.1 and two published worked examples.
Assumptions the tool makes
- Edge and corner groups. TR34 gives the ratio method for dual loads at an edge. The tool applies the same ratio to quadruple loads and to corners, which TR34 does not address.
- Closely spaced pairs. Pairs at centres up to 2h are merged into one load on the two equivalent circles plus the area between them. For punching, the merged load uses the rectangle enclosing both contact areas.
- Punching perimeters at edges and corners follow Figure 7.8, with the x dimension parallel to the edge. No ground reaction is deducted at a corner because TR34 gives no expression for it.
- Punching at joints. At an edge or corner the punching load is the design load times (1 − load transfer %), following 7.7 ("effective loads at joints are reduced by load transfer"). Dowel capacity is not deducted from the punching load. TR34 does not set out the punching check at a joint in more detail.
- Group punching. A perimeter around the whole group is checked in addition to each load, following the published worked example. TR34 does not state this.
- Fabric. Mp is Equation 3. Effective depth is thickness less bottom cover less one wire diameter. Fabric is assumed to be in the bottom of the slab. TR34 says fabric near the top only should be treated as unreinforced, so enter that case as plain concrete.
- Line load near a free edge is interpolated in a straight line from 3λMun at the edge to 4λMun at 3/λ, as drawn in Figure 7.9.
- Dowel capacity is entered by the user. Section 6.5 (Equations 16 to 19, bursting, and the 0.9l effective length of joint) is not built in.
Assumptions in the newer checks
- Fibre plus bars. Effective depth is to the bars, thickness less cover less one bar diameter. The bars' As is per metre in one direction; use the smaller direction if they differ. Punching uses the Eurocode 2 shear strength with the bar ratio, plus the steel fibre enhancement of Equation 14.
- Appendix C uses the effective depth to the bars for the 0.3d limit where bars are present, and the full thickness for fibre alone.
- Equation 36 is used as printed, with Mp, unless Mn is chosen. The check line gives the capacity on the other basis for comparison.
- Defined distributed loads are one or two parallel strips of the same intensity, each of which may be loaded or empty, and the peak moments are found by scanning across the whole width rather than only at the centre of each strip and the centre of the aisle.
- Fatigue wheel spacing. Figure E1 is read as a straight line from 2.0 at zero spacing to 1.0 at s/l = 1, with l at the required thickness.
- Large contact areas. TR34 sets no upper limit on a/l. The tool stops the a/l ≥ 0.2 equations where their denominators reach zero, rather than report the negative or unbounded capacity they would give, and warns where a exceeds l.
- Fatigue and fibre. The check is not run for fibre or fibre-plus-bar slabs, following Appendix E, Note 2.
Checked against printed values so far
- The newer checks have fewer printed values to compare against. Equations 36 and 37 reproduce TR34's own Equation 35 coefficient of 5.95 for the pattern of Figure 7.10(b). Equations 9 and 10 and Appendix C agree within 1% for fibre-plus-bar sections above 0.15%, as they should. A Tekla Tedds calculation to the 4th edition (fabric, 1000 × 1000 internal load) matches every printed value from fctd,fl through both punching capacities. Three 3rd edition worked calculations confirm the Meyerhof equations, the merged-load rule of 7.8.2, the Hetényi coefficients, l and λ, using each example's own moment capacities. No published worked example has been found yet for the 4th edition fibre moment capacity, tyre contact area or Appendix E.
References
- The Concrete Society, Concrete Industrial Ground Floors: A Guide to Design and Construction, Technical Report 34, 4th edition, 2013 (reprinted with amendments March 2016).
- Meyerhof, G. G., "Load Carrying Capacity of Concrete Pavements," Journal of the Soil Mechanics and Foundations Division, ASCE, 1962.
- Hetényi, M., Beams on Elastic Foundation, University of Michigan Press, 1946.
- Juhász, P. K., and Schaul, P., "Design of Industrial Floors: TR34 and Finite Element Analysis (Part 2)," Journal of Civil Engineering and Architecture, Vol. 13, 2019.
- WY, "Design Calculation, Slab-on-grade," steel fibre slab to TR34 3rd edition (worked example used to check the Meyerhof and Hetényi equations).
- "Design of Surface Beds Using TR34 Method," 150 mm slab example, TR34 3rd edition (worked example used to check l, λ and the Hetényi coefficient).
- Mayhew, H. C., and Harding, H. M., Thickness Design of Concrete Roads, TRRL Research Report 87, Transport and Road Research Laboratory, 1987 (basis of TR34 Appendix E).
- Ubani, O., "Design of Industrial Ground Floor Slabs," Structville (worked example used to check this tool).